Send Message

 

Noker Electric, your professional electrical partner !

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsSolid State Soft Starter

Motor Control Thyristor Solid State Soft Starter 1000KW Aluminum Zinc Plate Material

Certification
Good quality Bypass Soft Starter for sales
Good quality Bypass Soft Starter for sales
I'm Online Chat Now

Motor Control Thyristor Solid State Soft Starter 1000KW Aluminum Zinc Plate Material

China Motor Control Thyristor Solid State Soft Starter 1000KW Aluminum Zinc Plate Material supplier

Large Image :  Motor Control Thyristor Solid State Soft Starter 1000KW Aluminum Zinc Plate Material

Product Details:

Place of Origin: China
Brand Name: Noker
Certification: ISO9001
Model Number: NKS300-1000-10

Payment & Shipping Terms:

Minimum Order Quantity: 1 set
Price: To be discussed later
Packaging Details: Wooden Packing
Delivery Time: 15-20 work days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 300 set per month
Detailed Product Description
Material: Aluminum Zinc Plate Protection: Perfect Motor Protection
Display: LCD/touch Screen Display Reliability And Stability: High Reliability And Excellent Stability.
Dv/dt: Low Dv/dt Communication: Modbus RTU
High Light:

low voltage metal clad switchgear

,

safety electrical switchgear

1000KW Aluminum Zinc Platematerial For Motor Control Thyristor Solid State Soft Starter

 

AC10KV Medium Voltage 1000KW Thyristor Soft Starter for Motor Control/ Water Pump is a high voltage motor soft starter designed with up-to date concept,and mainly applicable to the control of and protection for the starting and stopping of squirrel-cage type asynchronous and synchronous motors.The starter is composed of several thyristors in series-parallel,and it can meet different current and voltage requirements.

The product is widely used in electric industry with rated voltage 3000 to 10000V,building materials chemical industry,metallurgy,steel and paper-making industries etc.,and can perform well if used together with various kinds of electromechanical devices including water pumps,fans,compressors,crashers,agitators and conveyer belt etc.,It is the ideal device for starting and protecting high voltage motors.
 

Terminal Description

 

Terminal No. Definition of terminal Description
Control circuit Analogue output X1/1 Current output (+) set by parameter items C06, C07
X1/2 Current output (-)
Digital input X1/3 COM COM
X1/4 Input terminal for remote run (RUN) Jump X1/3,X1/4 to run
X1/5 Input terminal for remote stop (STOP) Disconnect X1/3,X1/5 to stop
X1/6 Terminal for programmable digital input signal D1 Set by parameter item C03
X1/7 Terminal for programmable digital input signal D2 Set by parameter item C04
Current sampling X2/1 Input terminal for L1 phase current sampling To sample phase current of L1
X2/2
X2/3 Input terminal for L3 phase current sampling To sample phase current of L3
X2/4
Analogue input X2/5 PE for input signal Reference grounding for input current signal
X2/6 Analogue input Set by parameter item C06
RS 485-A X2/7 RS 485 communication (+)  
RS 485-B X2/8 RS 485 communication (-)  
Output relay K1 X3/1 Programmable output relay contact(default set: fault output) K11 and K12 are closed when the relay is powered. Contact capacity: AC250V/5A, DC30V/5A
X3/2
Output relay K2 X3/3 Output relay contact for bypass K21 and K22 are closed when the relay is powered. Contact capacity: AC250V/5A, DC30V/5A
X3/4
Output relay K3 X3/5 Programmable output relay contact K31 and K32 are closed when the relay is powered. Contact capacity: AC250V/5A, DC30V/5A
X3/6
Control voltage X3/7 PE To earth
X3/8 Control voltage AC110V---AC220V+15% 50/60Hz
 
Technical Indicators

 

Basic parameters
Type of load Three-phase squirrel cage asynchronous and synchronous motors
AC voltage 3000---10000VAC
Service frequency 50HZ/60HZ±2HZ
Phase sequence Allowed to work with any phase sequence
Composition of major loop (12SCRS,18SCRS,30SCRS depend on model)
Bypass contactor Contactor with direct starting capacity
Control power AC220V±15%
Transient voltage overload protection dv/dt snubber network
Start frequency 1-3 times per hour
Ambient condition Ambient temperature: -20°C -+50°C
Relative humidity: 5%----95% no condensation
Altitude less than 1500m (derating when altitude is more than 1500m)
Protective functions
Open-phase protection Cut off any phase of primary power supply in the course of starting or operation.
Over-current protection in operation Operational Over-current protection setting: 20~500%Ie
Unbalanced phase current protection Unbalanced phase current protection: 0~100%
Overload protection 10A,10,15,20,25,30,OFF
Underload protection Underload protection grade: 0~99%
Action time of underload protection: 0~250S
Start timeout Start time limit: 0~120S
Over-voltage protection When voltage of primary power supply is 120% higher than rated value, over-voltage protection is enabled.
Under-voltage protection When voltage of primary power supply is 70% lower than rated value, under-voltage protection is enabled.
Phase protection Allow to work with any phase sequence (through setting parameter)
Ground protection Protection available when grounding current is higher than set value
Description of communication
Protocol Modbus RTU
Communication interface RS485
Network connection Each  can communicate with 31 equipments in network.
Function Operation state and programming can be observed through communication interface.
Operating interface
LCD display LCD display/touch screen display
Language Chinese and English
Keyboard 6 touch membrane keyboard
Meter display
Voltage of primary power supply Display voltage of three-phase primary power supply
Three-phase current Display current of three-phase major loop
Data record
Fault history Record recent 15 faults information
History of number of starts Record number of starts of this soft starter

 

Features

 

1. Free of maintenance:Thyristor is an electric device without contacts. Different from other kinds of products that need frequent maintenance on liquid and parts etc., it turns the mechanical lift into the service life of electronic components, so it needs no maintenance after running for many years.

2. Easy installation and operation:NKS300 is a complete system for controlling and protecting the starting of motor. It can put into operation only with the power line and motor line connected. The whole system can be tested electrically under low voltage before operating with high voltage.

3. Backup:The starter comes equipped with a vacuum contactor which can be used to start the motor directly in the inside. If NKS300 fails, the vacuum contactor can be used to start the motor directly to ensure the continuity of the production.

4. High voltage thyristor is a component of major loop, equipped with voltage balancing protection system and over-voltage protection system.

5. NKS300 comes equipped with an electromagnetic blocking device for fear of entering the high voltage device in the electrified state.

6. Advanced optical fiber transmission technique realizes the triggering detection of high voltage thyristor and the isolation between LV control loops.

7. 32-bit ARM-core microcontroller is used to perform central control which is real-time and high efficient with , high reliability and excellent stability.

8. LCD/touch screen display system in both Chinese and English with human-friendly operation interface.

9. RS-485 communication port can be used to communicate with the upper computer or centralized control center.

10. Aging experiments are made on all circuit boards.

 

Catalogue 

 

Voltage Model Rated Current (A) W (mm) H(mm) L (mm)
3000V NKS300-400-3 100 1000 2300 1500
NKS300-630-3 150
NKS300-1600-3 400 1300 2300 1600
NKS300-2500-3 ≥600 Reserved
6000V NKS300-420-6 50 1000 2300 1500
NKS300-630-6 75
NKS300-1250-6 150
NKS300-1600-6 200 1300 2300 1600
NKS300-2500-6 300
NKS300-3300-6 400
NKS300-4150-6 500
NKS300-5000-6 ≥600 Reserved

 

 

 

 

 

10000V

NKS300-420-10 30 1000 2300 1500
NKS300-630-10 45
NKS300-800-10 60
NKS300-1250-10 90
NKS300-1500-10 110
NKS300-1800-10 130
NKS300-2250-10 160
NKS300-2500-10 180
NKS300-2800-10 200
NKS300-3500-10 250
NKS300-4000-10 280
NKS300-4500-10 320 1300 2300 1600
NKS300-5500-10 400
NKS300-6000-10 430
NKS300-7000-10 500
NKS300-8500-10 ≥600 Reserved

 

Connection Diagram

 

Motor Control Thyristor Solid State Soft Starter 1000KW Aluminum Zinc Plate Material

Motor Control Thyristor Solid State Soft Starter 1000KW Aluminum Zinc Plate Material

 

Maintenance


The working field should be regularly cleaned to reduce dust in ambient environment.The low and high voltage bins of NKS300 series high voltage soft starter should be regularly cleaned. It is necessary to use a brush or blower to remove dust inside bin (period less than 20 days)
It is also important to clean thyristor valve block. A blower with big power can be used to clean the valve block by blowing from up to down. Clean the field after blowing the thyristor valve block (period less than 6 months)
To ensure the normal operation, NKS300 series high voltage soft starter should be regularly dehumidified if the working field is wet. (Period is depended on the circumstance)
Considering that there is shake in working field when the soft starter is started, the secondary control wiring of NKS300 series high voltage soft starter should be regularly checked to examine whether the connecting terminal is loose. If yes, tighten the loose connecting terminal. (3 months as a period)

 

Packaging

 

Motor Control Thyristor Solid State Soft Starter 1000KW Aluminum Zinc Plate Material

Contact Details
Xi'an Noker Electric Co.,Ltd.

Contact Person: Sales Manager

Send your inquiry directly to us (0 / 3000)