Send Message

 

Noker Electric, your professional electrical partner !

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsBypass Soft Starter

Small Size Light Weight Bypass Soft Starter With Fire Proof Housing Long Life

Certification
Good quality Bypass Soft Starter for sales
Good quality Bypass Soft Starter for sales
I'm Online Chat Now

Small Size Light Weight Bypass Soft Starter With Fire Proof Housing Long Life

China Small Size Light Weight Bypass Soft Starter With Fire Proof Housing Long Life supplier

Large Image :  Small Size Light Weight Bypass Soft Starter With Fire Proof Housing Long Life

Product Details:

Place of Origin: China
Brand Name: Noker
Certification: ISO9001
Model Number: NK-ASSU380P12

Payment & Shipping Terms:

Minimum Order Quantity: 5 set
Price: Depend on quantity
Packaging Details: Carton Packing
Delivery Time: 5-8 work days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 2000 set per month
Detailed Product Description
Dimension: Small Size, Light Weight Protection: Perfect Motor Protection
Material: Fire Proofed Housing Reliability: High Reliability And Long Life
Shock And Drive Stress: Relieves Shock And Drive Train Stress On Startip Start\stop: Produces Smoother Starts And Stops
High Light:

single phase soft starter

,

compressor soft starter

,

soft start starter

Three Phase 380VAC 12P Hot Pump Motor Soft Starter Limit Inrush Current

 

The soft start controller – NK-ASSU380P12 provides an effective solution in reduction of start-up current, typically up to 70%, but still provides full startup torque for compressors and motors. Across the line starting of air-conditioner compressor or induction motors is accompanied by inrush currents up to 7-8 times higher than running current, and starting torque up to 3 times higher than running torque. The increased unnecessary torque results in sudden mechanical stress on the machine which leads to increased wear and higher service costs and reduced service life. Moreover, the high inrush current and current peaks may stress the power supply system to increased mains and generator loads which may lead to voltage dips results in breaking down of other valuable equipment or system function.

 

NK-ASSU380P12 is an embedded design soft start controller. It regulates the start-up voltage of the compressor/motor intelligently to effectively reduce the inrush and surge current while starting-up, thus consume much less power from the public utility network or on-site AC power supply system but still provides full startup torque for compressors and motors.

 

NK-ASSU380P12 effective limits the inrush current and so improves stability of the power supply and reduces transient voltage drops that may affect or break down other loads. This will eliminate the need of over dimension of the power supply system which results in reduce capital expenditure investment in power supply capacity, charge meter, circuit breaker and power wire line capacity etc..and extend the service life of
the motor or compressor effectively.

 

NK-ASSU380P12 is suitable for all three-phase air conditioner and heat pump and motor with horse power less than 12P.

 

Electrical:

 

1. Applicable compressor power: 380V/12P/3PH ,190V/7HP/3PH (Rated current below 24A)
2. Operating Voltage Range: 340~460VAC
3. Control voltage: 220VAC
4. Rated operational current: 24A
5. Starting current: ≤80A/2.5S (Rated operating current within 3 times)
6. Surge current resistance: 250A/20mS
7. Depletion current: ≤50mA
8. Dissipation power: <10VA
9. Soft start time: ≤2.5s
10. Performance period: 45 thousand hours (within rated operating temperature range)
11. Number of starts: 100 thousand times (normal environment, the interval is not less than 3 minutes)

 

Features:

 

1. Limits inrush current
2. Eliminates current surges & voltage drops
3. Extends motor/compressor service life with built-in electronic overload protective relay
4. Integral bypass contactor reduces heat generation
5. Produces smoother starts and stops by controlling torque
6. Reduces vibration and mechanical damage
7. Relieves shock and drive train stress on startup
8. Easy to wire and install and decreases equipment downtime
9. High reliability and long life

 

Protection:


1. The insulation resistance between housing and chassis: > 300 M Ω.
2. Withstand voltage between housing and chassis: >3000 VAC in 1 minute.
3. Shock resistance better than 200m/s2 and 11ms.
4. Anti vibration: 10~55mm(double amplitude, 1.5mm)
5. Protection restart time interval: 180 seconds

 

Environment:

 

1. Operating temperature range: -20~+65℃
2. Flame retardation: Insulating materials have flame retardant properties
3. Relative humidity: 0—95%
4. Shock resistance: 200m/s2 11ms
5. Anti-knock: 10~55mm (double amplitude 1.5mm)
6. Rust-resisting property: Each metal component can withstand salt spray test for at least 24 hours

 

Typical application:

 

Small Size Light Weight Bypass Soft Starter With Fire Proof Housing Long LifeSmall Size Light Weight Bypass Soft Starter With Fire Proof Housing Long Life

 

Small Size Light Weight Bypass Soft Starter With Fire Proof Housing Long Life

 

Contact Details
Xi'an Noker Electric Co.,Ltd.

Contact Person: Sales Manager

Send your inquiry directly to us (0 / 3000)